Malibu Power Wedge Fault Repair
Malibu Power Wedge Fault Repair
Malibu Power Wedge Fault Repair
Malibu Power Wedge Fault Repair
Malibu Power Wedge Fault Repair
Malibu Power Wedge Fault Repair

Malibu Power Wedge Fault Repair

Malibu Power Wedge faults in 2012 - 2014 model year boats are typically caused by a circuit board failure of the Lenco Viper H-bridge module. Manufacturer replacements are no longer available for this part. 

Wakeswitches mail-in repair service will restore your original Lenco Power Wedge module and solve the fault alarm. 

 

Compatible models: 2012 - 2014 Malibu boats (including 2015 VTX), with Lenco Viper H-Bridge. The label on the text must indicate "5 lobe".

Repair Process:

  1. Add this product to your cart and check out
  2. Unplug and remove your Lenco Power Wedge module
  3. Use the shipping label we email you to send in your module
  4. Wakeswitches expert technicians perform the repair, conduct in-boat QC testing, and return ship your unit

Turnaround time: 3-4 business days from tech center arrival

Warranty: Repaired components are covered by a one-year warranty

 

For other Power Wedge related faults, including over-current alarms, check for these common issues:

  1. Blown 20A wedge fuse (found in an red in-line fuse holder under the dash)
  2. Blown 5A wedge fuse (found in main fuse panel under the dash)
  3. Failed actuator rams - with rams disconnected from the wedge frame, connect the ram's leads to a 12V battery to function test. Each ram should move at the same speed. Differing speeds will cause binding.
  4. Binding wedge movement - with rams disconnected, check the wedge mechanism swings freely